| Availability: | |
|---|---|
Intuitive menu navigation system and 5.6-inch color LCD touch screen, in line with daily operation habits, easy to use
It is designed and manufactured in full accordance with the new national law of Fast Digestion-Spectrophotometric Method (HJ/T 399-2007)It is in line with JG975-2002 Chemical 0xygen Demand (COD) meters verification regulations. It is suitable for all kinds of domestic sewage and industrial wastewater detection.
As a professional water quality analyzer, the determination result is direct reading, stable and accurate.
It has a multi-light path non-interference system, and can measure COD, ammonia nitrogen, total phosphorus, total nitrogen and turbidity. it upports two kinds of colorimetry, namely, cell colorimetry and tube calorimetry.
With data storage function, can store 16,000 groups of data, and can be freely viewed.
The water quality meter equipped with a digestion device, which has the functions of intelligent heating, intelligent timing and delay protection, et., and can digest water samples.
Equipped with a complete professional consumable reagent, the working steps are greatly reduced, and the measurement is more simple and accurate.
With the calibration function, the curve can be calculated and stored according to the standard sample, no need to make the curve manually.
The printer can print current data and store historical data.
Benchtop multiparameter water quality meter is equipped with USB interface and infrared transmission function, can transfer the stored historical data to the computer.
Adopt the mould shell of patent desian, the instrument is beautiful and generous.
| Model | MWQ-B6C | ||||
|---|---|---|---|---|---|
| Performance parameters | |||||
| ltem | COD | Ammonia nitrogen | Total phosphorus | Turbidity | Total nitrogen |
| Range | 2-10000mg/L (Subsection) | 0.02-100mg/L (Subsection) | 0.01-12mg/L (Subsection) | 1-300NTU | 1-100mg/L (Subsection) |
| Indication Error | COD≤ 50mg/L; ≤8% | ≤±5% | ≤±5% | ≤±10% | ≤±10% |
| COD>50mg/L; ≤5% | |||||
| Limits of Detection | 2mg/L | 0.02mg/L | 0.01mg/L | 1NTU | 0.5mg/L |
| Anti Chloride Interference | [CL-]<1000mg/L No influence | -- | -- | -- | -- |
| [CL-]<4000mg/L (Optional) | |||||
| Optical Stability | <0.005A/20min | ||||
| Repeatability | ≤±2% | ||||
| Batch Processing | 12 | ||||
| Digestion Time Error | ≤±2% | ||||
| Temperature Indication Error | ≤±2℃ | ||||
| Temperature Filed Uniformity | ≤2℃ | ||||
| Temperature Range | (45~190)℃ | ||||
| Working Parameter | |||||
| Ambient Temperature | (5~40)℃ | ||||
| Ambient Humidity | Relative humidity≤85%RH ( non-condensing ) | ||||
| Rated Voltage | AC220V+10%/50Hz | ||||
| Power | 620W | ||||
| Physical Parameters | |||||
| Key Spare Parts | Interference filter | ||||
| Key Spare Parts | Platinum resistance | ||||
| Overall Size (mm) | 450x350x235 | ||||
| Display | 5.6-inch color LCD touch screen | ||||
| Colorimetric Method | Cuvette/Tube | ||||
| Printer | Thermal line printer | ||||
| Communications | USB/infrared | ||||
| Curve | 132(standard curves: 108, fitting curves: 24) | ||||
| Data Storage | 16000 | ||||
| N.W. / G.W. (kg) | 10.8 / 21.9 | ||||
| Shipping Size (WxDxH)(mm) | 595x485x535 | ||||
Intuitive menu navigation system and 5.6-inch color LCD touch screen, in line with daily operation habits, easy to use
It is designed and manufactured in full accordance with the new national law of Fast Digestion-Spectrophotometric Method (HJ/T 399-2007)It is in line with JG975-2002 Chemical 0xygen Demand (COD) meters verification regulations. It is suitable for all kinds of domestic sewage and industrial wastewater detection.
As a professional water quality analyzer, the determination result is direct reading, stable and accurate.
It has a multi-light path non-interference system, and can measure COD, ammonia nitrogen, total phosphorus, total nitrogen and turbidity. it upports two kinds of colorimetry, namely, cell colorimetry and tube calorimetry.
With data storage function, can store 16,000 groups of data, and can be freely viewed.
The water quality meter equipped with a digestion device, which has the functions of intelligent heating, intelligent timing and delay protection, et., and can digest water samples.
Equipped with a complete professional consumable reagent, the working steps are greatly reduced, and the measurement is more simple and accurate.
With the calibration function, the curve can be calculated and stored according to the standard sample, no need to make the curve manually.
The printer can print current data and store historical data.
Benchtop multiparameter water quality meter is equipped with USB interface and infrared transmission function, can transfer the stored historical data to the computer.
Adopt the mould shell of patent desian, the instrument is beautiful and generous.
| Model | MWQ-B6C | ||||
|---|---|---|---|---|---|
| Performance parameters | |||||
| ltem | COD | Ammonia nitrogen | Total phosphorus | Turbidity | Total nitrogen |
| Range | 2-10000mg/L (Subsection) | 0.02-100mg/L (Subsection) | 0.01-12mg/L (Subsection) | 1-300NTU | 1-100mg/L (Subsection) |
| Indication Error | COD≤ 50mg/L; ≤8% | ≤±5% | ≤±5% | ≤±10% | ≤±10% |
| COD>50mg/L; ≤5% | |||||
| Limits of Detection | 2mg/L | 0.02mg/L | 0.01mg/L | 1NTU | 0.5mg/L |
| Anti Chloride Interference | [CL-]<1000mg/L No influence | -- | -- | -- | -- |
| [CL-]<4000mg/L (Optional) | |||||
| Optical Stability | <0.005A/20min | ||||
| Repeatability | ≤±2% | ||||
| Batch Processing | 12 | ||||
| Digestion Time Error | ≤±2% | ||||
| Temperature Indication Error | ≤±2℃ | ||||
| Temperature Filed Uniformity | ≤2℃ | ||||
| Temperature Range | (45~190)℃ | ||||
| Working Parameter | |||||
| Ambient Temperature | (5~40)℃ | ||||
| Ambient Humidity | Relative humidity≤85%RH ( non-condensing ) | ||||
| Rated Voltage | AC220V+10%/50Hz | ||||
| Power | 620W | ||||
| Physical Parameters | |||||
| Key Spare Parts | Interference filter | ||||
| Key Spare Parts | Platinum resistance | ||||
| Overall Size (mm) | 450x350x235 | ||||
| Display | 5.6-inch color LCD touch screen | ||||
| Colorimetric Method | Cuvette/Tube | ||||
| Printer | Thermal line printer | ||||
| Communications | USB/infrared | ||||
| Curve | 132(standard curves: 108, fitting curves: 24) | ||||
| Data Storage | 16000 | ||||
| N.W. / G.W. (kg) | 10.8 / 21.9 | ||||
| Shipping Size (WxDxH)(mm) | 595x485x535 | ||||