Model | BSTC-250 | BSTC-460 | BSTC-760 | BSTC-860 | BSTC-1000 |
---|---|---|---|---|---|
Chamber Capaticy | 250L | 460L | 760L | 860L | 1000L |
Display | 7-inch LCD touch screen | ||||
Control Mode | Intelligent Fuzzy PID Control, Normal/Program Operation | ||||
Convection Method | Forced convection | ||||
Working Conditions | 5 ℃~35 ℃ (it is recommended to use an ambient temperature of 25~28 ℃) | ||||
Temperature Control Range | -10℃~+85℃ | ||||
Temperature Resolution | 0.1℃ | ||||
Temperature Control Accuracy | ±0.1℃ | ||||
Temperature Deviation(15~45℃) | ±0.2~0.6℃ | ||||
Insulation Material | Polyurethane integral foaming | ||||
Program Control | Programmable intelligence, program operation mode, and regular operation mode | ||||
Defrost Function | Automatic defrost or intermittent defrost | ||||
Test Hole | Φ 50, 75, 100 (choose one) | ||||
Refrigeration Method | Environmentally friendly variable frequency compression refrigeration technology | ||||
Temperature Sensor | German HERAEUS PT100 temperature sensor | ||||
Safety Setting | automatic start, automatic stop, Power resumption, scheduled operation, with compressor overpressure protection, overtemperature alarm, leakage protection, door open alarm, and sensor malfunction alarm functions. | ||||
Shelves | Three (Standard) | ||||
Optional Accessories | Printer, Computer monitoring software, Remote control alarm system | ||||
Power Supply | AC220V, 50/60Hz | ||||
Consumption | 1100W | 1200W | 2000W | 2000W | 2000W |
Chamber Size (W×D×H)(mm) | 670x410x912 | 750x560x1105 | 1180x500x1300 | 1200x450x1600 | 1200x720x1180 |
External Size (W×D×H)(mm) | 850x797x1510 | 933x960x1765 | 1490x887x1790 | 1390x937x1840 | 1390x1120x1840 |
Shipping Size (W×D×H)(mm) | 945x920x1700 | 1060x1015x2000 | 1620x1060x2000 | 1500x1160x2070 | 1620x1180x2000 |
N.W./G.W. (kg) | 160/185 | 210/235 | 295/330 | 310/345 | 355/390 |
Battery stability testing chamber is used for battery performance testing to ensure that the battery undergoes constant current and constant voltage charge/discharge processes, in order to analyze and evaluate the performance and behavior under the specified environmental conditions during the test.
Electronic PID control, intelligent operating system, high-performance processor
Utilizes a full-color LCD touch screen
Data recording and storage function; capable of storing test data for over 10 years; original data exportable via USB drive
Temperature data can be viewed through curve display
Features event recording, permission management, multi-point temperature correction, and variable frequency refrigeration system
Equipped with Danfoss (SECOP) compressor and German EBM condensing fan, environmentally friendly refrigerant
Capacitive temperature sensor
Box insulation material using integrated polyurethane foam technology
Double-door structure design, with tempered glass inner door
The standard communication interfaces USB, RS485, and RS232 are reserved for the cabinet
Model | BSTC-250 | BSTC-460 | BSTC-760 | BSTC-860 | BSTC-1000 |
---|---|---|---|---|---|
Chamber Capaticy | 250L | 460L | 760L | 860L | 1000L |
Display | 7-inch LCD touch screen | ||||
Control Mode | Intelligent Fuzzy PID Control, Normal/Program Operation | ||||
Convection Method | Forced convection | ||||
Working Conditions | 5 ℃~35 ℃ (it is recommended to use an ambient temperature of 25~28 ℃) | ||||
Temperature Control Range | -10℃~+85℃ | ||||
Temperature Resolution | 0.1℃ | ||||
Temperature Control Accuracy | ±0.1℃ | ||||
Temperature Deviation(15~45℃) | ±0.2~0.6℃ | ||||
Insulation Material | Polyurethane integral foaming | ||||
Program Control | Programmable intelligence, program operation mode, and regular operation mode | ||||
Defrost Function | Automatic defrost or intermittent defrost | ||||
Test Hole | Φ 50, 75, 100 (choose one) | ||||
Refrigeration Method | Environmentally friendly variable frequency compression refrigeration technology | ||||
Temperature Sensor | German HERAEUS PT100 temperature sensor | ||||
Safety Setting | automatic start, automatic stop, Power resumption, scheduled operation, with compressor overpressure protection, overtemperature alarm, leakage protection, door open alarm, and sensor malfunction alarm functions. | ||||
Shelves | Three (Standard) | ||||
Optional Accessories | Printer, Computer monitoring software, Remote control alarm system | ||||
Power Supply | AC220V, 50/60Hz | ||||
Consumption | 1100W | 1200W | 2000W | 2000W | 2000W |
Chamber Size (W×D×H)(mm) | 670x410x912 | 750x560x1105 | 1180x500x1300 | 1200x450x1600 | 1200x720x1180 |
External Size (W×D×H)(mm) | 850x797x1510 | 933x960x1765 | 1490x887x1790 | 1390x937x1840 | 1390x1120x1840 |
Shipping Size (W×D×H)(mm) | 945x920x1700 | 1060x1015x2000 | 1620x1060x2000 | 1500x1160x2070 | 1620x1180x2000 |
N.W./G.W. (kg) | 160/185 | 210/235 | 295/330 | 310/345 | 355/390 |
Battery stability testing chamber is used for battery performance testing to ensure that the battery undergoes constant current and constant voltage charge/discharge processes, in order to analyze and evaluate the performance and behavior under the specified environmental conditions during the test.
Electronic PID control, intelligent operating system, high-performance processor
Utilizes a full-color LCD touch screen
Data recording and storage function; capable of storing test data for over 10 years; original data exportable via USB drive
Temperature data can be viewed through curve display
Features event recording, permission management, multi-point temperature correction, and variable frequency refrigeration system
Equipped with Danfoss (SECOP) compressor and German EBM condensing fan, environmentally friendly refrigerant
Capacitive temperature sensor
Box insulation material using integrated polyurethane foam technology
Double-door structure design, with tempered glass inner door
The standard communication interfaces USB, RS485, and RS232 are reserved for the cabinet