Availability: | |
---|---|
1. User Friendly Software
Easy operate with iconic interface
Multi-language available
Easy reagent parameters setting
Support batch request, panel/calculation test
Print out report template editable
Auto troubleshoot failure and recovery
Powerful statistic system
Manual dilution, auto dilution and post dilution
Easy rerun and restore test
2. Calibration & QC
Multiple calibration mode
Advanced algorithm to obtain best calibration curve
Multi QC rules: Westgard, Cumulative sum check, Twin plot
3. Real Time Monitoring
Reaction curve, calibration test and QC test curve
Sample, reagent and reaction cuvette status
Lamp intensity, water tank and waste tank status
Reaction disk and reagent disk temperature
Model | BA-300I |
---|---|
Category | Random access, fully automatic chemistry analyzer |
Throughput | 240 tests/hour(without ISE),315 tests/hour(with ISE) |
Methodology | End point, Fixed Time, Kinetic |
Reagent | Open system |
Reagent Position | 40 |
Sample Position | 40 |
Minimum Reaction Volume | 150uL |
Carryover | <0.005% |
Water Consumption | Low to 5L/Hour |
Maximum Reaction Time | 19.1 minutes (Single reagent), 15.7 minutes(Dual reagent) |
Maximum Reaction Volume | 500 uL |
Principle | Colorimetry, Turbidimetry |
Testing Mode | Regular mode (single&dual reagents), fast mode (single reagent) |
Sample Mode | Random access, STAT sample priority |
Sample Volume | 2~50uL, step by 0.1 uL |
Sample Disk | 40 positions |
Sample/reagent Probe | One probe for sample and reagent with liquid level detection, vertical and horizontal collision protection and reagent volume real time monitoring function |
Sample Tube | Regular sample tube (13x100mm, 13x75 mm, 12x100 mm, 12x75 mm), Vacuum tube, eppendorf tube, plastic tube, etc. |
Reagent Volume | R1:150-450 uL, R2:10-300uL, step by 1uL |
Reagent Disk | 40 reagent positions, 24 hours water cooling, 4-12℃ |
Reagent Bottles | Compatible with Olympus and Hitachi reagent bottles |
Mixer | High polished nano material mixer |
Reaction Cuvettes | 81 cuvettes, semi-permanent rigid UV special plastic cuvettes |
Wash Station | 6-step auto wash station |
Reaction Temperature | 37±0.1°C |
Heater | Metal thermostat for reaction disk |
Lamp | Halogen Tungsten lamp, 12V20W, about 2000hours, water cooling system |
Filter | FMSS(Full-sealed Matrix Spectrometric System) |
Wavelength | 8 wavelengths: 340,405,450,510,546,578,630,670nm |
Resolution | 0.0001Abs |
Linearity Range | 0-3.5Abs |
Accuracy | 0.5A: <±0.02AbS, 1.0A: <±0.04Abs |
Stray Light | >4.5 |
Stability | <0.01Abs/hour |
CV | <1.5% |
Half Band Accuracy | ±2nm |
Detector | Photodiode detector array |
Calibration Mode | One point linear, two point linear, multi-point linear, Logit-4P, Logit-5P, spline, exponential, polynomial |
Calibration Curve | Calibration curve auto check, auto curve fitting |
QC Rule | Westgard multi-rule.Cumulative sum check, Twin Plot |
QC Curve | Westgard multi-rule, Cumulative sum check, Twin Plot |
QC Warning | Out of control auto warning, data automatic record and analysis |
Operating System | Windows 7/10 |
Data Storage | Decided by computer hard disc capacity |
LIS Interface | Bi-LlS interface |
Print Mode | Multi default formats, user-defined formats |
System Monitor | Real time monitoring for sample disk, reagent disk, reaction disk. Real time monitoring for QC status. Real time monitoring for reaction cuvettes status, lamp status and temperature. Real time monitoring for reagent volume, reaction curve, calibration curve and QC curve. Linearity range limitation, substrate exhaustion judgement and prozone detecting. Abnormal status warning. |
Other Function | User authority setting,test panel function, calculated/manual parameters programing, carryover setting, sample and reagent blank auto calculation, automatic failure recovery, automatic print, data statistic,auto/manual dilution test. auto retest. |
PC Configration | CPU 2.5GHz, memory 4GB, hard disc 500G 19 inch widescreen monitor |
PC Interface | RS-232C |
Size(LxDxH)(mm) | 855x550x 580 |
Power Supply | AC 100-240V. 50/60Hz±1 Hz.,≤350VA |
Net Weight | 75Kg |
Optional Parts | Barcode reader, Water purification module, PC with touch screen, HP laser printer |
Reaction System:
50 high light transmittance reaction cuvettes
Metal thermostat ensures stable temperature: 37℃
Auto water blank test ensures precise results
Sample & Reagent Disk
24 hours reagent refrigerator: 4-12℃
Noise free water cooling design
40 positions for reagent
40 positions for sample with STAT priority
Optional barcode scanner available
Sampling System
High polished nano material sample/reagent probe
High accuracy ceramic syringe
Auto depth adjustment
Liquid level detection, vertical and horizontal collision protection
Maintenance free rotor with stable movement
Anti-contamination Design
6-step wash station washes cuvettes with wash solution
High polished nano material mixer
Automatic probe and mixer washing
Intelligent anti-contamination program
Fluid System
Branded components including: IWAKl pump, SMC valve, Ceramic syringe, THOMAS peristaltic pump, Tygon tubing and CPC tubing couplings
Built-in degasser ensures precise sampling
Optical System
Halogen tungsten lamp with about 2000H life time
Full-sealed matrix spectrometric system
Simultaneously dual wavelength detection to avoid interference
Silent water cooling design
Optional
Internal PC with touch screen
Barcode Reader
1. User Friendly Software
Easy operate with iconic interface
Multi-language available
Easy reagent parameters setting
Support batch request, panel/calculation test
Print out report template editable
Auto troubleshoot failure and recovery
Powerful statistic system
Manual dilution, auto dilution and post dilution
Easy rerun and restore test
2. Calibration & QC
Multiple calibration mode
Advanced algorithm to obtain best calibration curve
Multi QC rules: Westgard, Cumulative sum check, Twin plot
3. Real Time Monitoring
Reaction curve, calibration test and QC test curve
Sample, reagent and reaction cuvette status
Lamp intensity, water tank and waste tank status
Reaction disk and reagent disk temperature
Model | BA-300I |
---|---|
Category | Random access, fully automatic chemistry analyzer |
Throughput | 240 tests/hour(without ISE),315 tests/hour(with ISE) |
Methodology | End point, Fixed Time, Kinetic |
Reagent | Open system |
Reagent Position | 40 |
Sample Position | 40 |
Minimum Reaction Volume | 150uL |
Carryover | <0.005% |
Water Consumption | Low to 5L/Hour |
Maximum Reaction Time | 19.1 minutes (Single reagent), 15.7 minutes(Dual reagent) |
Maximum Reaction Volume | 500 uL |
Principle | Colorimetry, Turbidimetry |
Testing Mode | Regular mode (single&dual reagents), fast mode (single reagent) |
Sample Mode | Random access, STAT sample priority |
Sample Volume | 2~50uL, step by 0.1 uL |
Sample Disk | 40 positions |
Sample/reagent Probe | One probe for sample and reagent with liquid level detection, vertical and horizontal collision protection and reagent volume real time monitoring function |
Sample Tube | Regular sample tube (13x100mm, 13x75 mm, 12x100 mm, 12x75 mm), Vacuum tube, eppendorf tube, plastic tube, etc. |
Reagent Volume | R1:150-450 uL, R2:10-300uL, step by 1uL |
Reagent Disk | 40 reagent positions, 24 hours water cooling, 4-12℃ |
Reagent Bottles | Compatible with Olympus and Hitachi reagent bottles |
Mixer | High polished nano material mixer |
Reaction Cuvettes | 81 cuvettes, semi-permanent rigid UV special plastic cuvettes |
Wash Station | 6-step auto wash station |
Reaction Temperature | 37±0.1°C |
Heater | Metal thermostat for reaction disk |
Lamp | Halogen Tungsten lamp, 12V20W, about 2000hours, water cooling system |
Filter | FMSS(Full-sealed Matrix Spectrometric System) |
Wavelength | 8 wavelengths: 340,405,450,510,546,578,630,670nm |
Resolution | 0.0001Abs |
Linearity Range | 0-3.5Abs |
Accuracy | 0.5A: <±0.02AbS, 1.0A: <±0.04Abs |
Stray Light | >4.5 |
Stability | <0.01Abs/hour |
CV | <1.5% |
Half Band Accuracy | ±2nm |
Detector | Photodiode detector array |
Calibration Mode | One point linear, two point linear, multi-point linear, Logit-4P, Logit-5P, spline, exponential, polynomial |
Calibration Curve | Calibration curve auto check, auto curve fitting |
QC Rule | Westgard multi-rule.Cumulative sum check, Twin Plot |
QC Curve | Westgard multi-rule, Cumulative sum check, Twin Plot |
QC Warning | Out of control auto warning, data automatic record and analysis |
Operating System | Windows 7/10 |
Data Storage | Decided by computer hard disc capacity |
LIS Interface | Bi-LlS interface |
Print Mode | Multi default formats, user-defined formats |
System Monitor | Real time monitoring for sample disk, reagent disk, reaction disk. Real time monitoring for QC status. Real time monitoring for reaction cuvettes status, lamp status and temperature. Real time monitoring for reagent volume, reaction curve, calibration curve and QC curve. Linearity range limitation, substrate exhaustion judgement and prozone detecting. Abnormal status warning. |
Other Function | User authority setting,test panel function, calculated/manual parameters programing, carryover setting, sample and reagent blank auto calculation, automatic failure recovery, automatic print, data statistic,auto/manual dilution test. auto retest. |
PC Configration | CPU 2.5GHz, memory 4GB, hard disc 500G 19 inch widescreen monitor |
PC Interface | RS-232C |
Size(LxDxH)(mm) | 855x550x 580 |
Power Supply | AC 100-240V. 50/60Hz±1 Hz.,≤350VA |
Net Weight | 75Kg |
Optional Parts | Barcode reader, Water purification module, PC with touch screen, HP laser printer |
Reaction System:
50 high light transmittance reaction cuvettes
Metal thermostat ensures stable temperature: 37℃
Auto water blank test ensures precise results
Sample & Reagent Disk
24 hours reagent refrigerator: 4-12℃
Noise free water cooling design
40 positions for reagent
40 positions for sample with STAT priority
Optional barcode scanner available
Sampling System
High polished nano material sample/reagent probe
High accuracy ceramic syringe
Auto depth adjustment
Liquid level detection, vertical and horizontal collision protection
Maintenance free rotor with stable movement
Anti-contamination Design
6-step wash station washes cuvettes with wash solution
High polished nano material mixer
Automatic probe and mixer washing
Intelligent anti-contamination program
Fluid System
Branded components including: IWAKl pump, SMC valve, Ceramic syringe, THOMAS peristaltic pump, Tygon tubing and CPC tubing couplings
Built-in degasser ensures precise sampling
Optical System
Halogen tungsten lamp with about 2000H life time
Full-sealed matrix spectrometric system
Simultaneously dual wavelength detection to avoid interference
Silent water cooling design
Optional
Internal PC with touch screen
Barcode Reader