An economical analytical instrument with optional RS232 interface output and excellent photometry accuracy. Widely used in many fields such as medical testing, food, petrochemical industry, environmental protection and monitoring, etc.
LCD display directly displays the standard curve and test data. The host can store the test data and optionally print it with a printer.
USB data output interface, optional professional software for online operation.
Built-in analysis software, standard curve can be used for related tests, it can perform continuous testing and store 200 sets of data, and can store 100 standard curves, which can be named directly by the user.
Uniquely designed optical system, high-performance 1200 lines/mm grating and imported receiver.
Automatic wavelength calibration, automatic wavelength setting.
The large sample room can accommodate cuvettes of various sizes from 5 to 100 mm.
Ultra-thin buttons, simple and convenient to operate.
Optional disc rotating automatic eight-link sample holder, with good reliability and centered light spot.
| Model | SP-V723G | SP-V723N |
|---|---|---|
| Optical System | Split beam detection | |
| Display | LCD | |
| Wavelength Setting | Automatic | |
| Bandwidth (nm) | 4 | 2 |
| Wavelength Range | 320–1100 nm | |
| Photometric Range | -3.0 to 3.0 A, 0-200%T, 0.000-9999 C | |
| Scanning Speed | Fast-Medium-Slow | |
| Wavelength Accuracy (nm) | ±1 | ±0.5 |
| Wavelength Repeatability (nm) | 0.5 | 0.2 |
| Photometric Accuracy | 0.5 %T | 0.2 %T |
| Photometric Repeatability | 0.2 %T | 0.15 %T |
| Stray Light | ≤0.1 %T@360nm | ≤0.05 %T@360nm |
| Stability | ±0.002 A/h@500nm | ±0.001 A/h@500nm |
| Sample Rack | Standard 10 mm sample rack | |
| Power Supply | AC 220/110 V, 50/60 Hz | |
| External Size(W×D×H) | 510×420×240 mm | |
| Shipping Size(W×D×H) | 680×560×320 mm | |
| N.W./G.W. | 12/16 kg | |

The display shows test data such as absorbance, concentration or wavelength, and the controls include functions such as on/off, mode selection, wavelength adjustment and calibration.



Heat sink to dissipate heat during prolonged operation

Use foam to cushion the instrument for protection.
A: It solves the biggest pain point of data drift caused by the unstable light source of single-beam instruments, while its price is usually much lower than that of traditional dual-beam instruments, giving customers excellent cost performance.
A: Split Beam Spectrophotometer demonstrates significant strengths in applications across the following 4 key areas:
1. Kinetic and time-course measurements, suitable for studies of enzyme kinetics, reaction rates, etc.
2. Full-spectrum scanning, eliminating the need for frequent baseline recalibration, resulting in excellent data reproducibility.
3. Long-term continuous batch testing, improving work efficiency.
4. Multi-wavelength determination, suitable for multi-component analysis.