Beyond the visible realm lies an invisible world composed of countless volatile molecules. Gas chromatography (GC) technology serves as a super-microscope that allows humanity to peer into this unseen world. Our GC-SK906 GC system equipped with precise temperature programming control, stable flow path design, and diverse high-sensitivity detectors, empowering clients to establish a core competitive advantage in regulatory compliance, quality control, process optimisation, and R&D innovation.

Gas Chromatography Feature:

  1. Intelligent EPC (Electronic Pressure Control) system with built-in ambient temperature and pressure compensation, supporting multiple modes, such as constant flow, constant pressure, and pulsed injection, to ensure superior reproducibility in qualitative and quantitative analysis.

  2. 10-inch HD independent control screen, real-time visualization of chromatograms, temperature and carrier gas flow. Supports PC-free editing of analytical methods, delivering smooth, independent operation.

  3. Innovative quick-release smart inlet, tool-free opening/closing, with automatic detection of the optimal seal position, integrated smart maintenance alerts and automatic gas leak testing.

  4. Dual-column oven temperature control system with 8-independent, precision-controlled temperature zones. Dual over-temperature protection for both the oven chamber and the chromatographic columns.

  5. Proprietary compliant chromatography data system supporting USB firmware upgrades and optional full-function audit trails to meet data integrity requirements.

  6. Intelligent self-diagnostic and recovery system,automatically identifying incorrect operations and proactively implementing self-protection measures to swiftly restore the initial settings.

  7. Highly scalable 4-detector platform compatible with detectors such as FID, TCD, FPD, and NPD, meeting diverse analytical needs.

企业微信截图_17817515919747.png
image.png
image.png

Advanced Full EPC Control

Tool-Free Smart Inlet

Cost-Saving Standalone 10 inch-Touchscreen

image.png
image.png
image.png

8-Zone Dual-Oven Thermal System

Intelligent Self-Diagnostics & Recovery

Quad-Detector High Extensibility

Gas Chromatography Specification:

Model

GC-SK906

Injection System

Manual injection

Inlet System

Inert Flow Path Split/Splitless (S/SL) Capillary Inlet

Detector

Flame Ionization Detector (FID)

Software

Basic (Audit function optional)

Hydrogen Generator

Yes

Air Generator

Yes

Inlet System (EPC Controlled)

Inlet Type

Inert Flow Path Split/Splitless (S/SL) Capillary Inlet

Maximum Operating Temperature

450 °C

Pressure Control Precision

±0.001 psi

Flow Rate Setting Range

0–500 mL/min; 0–1250 mL/min (customizable for high-flow applications)

Flow Rate Setting Precision

±0.01 mL/min

Programmable Flow Ramps

≥ 20 ramps

Split & Purge Trap Configuration

Equipped with dedicated split vent trap and septum purge trap as standard

EPC Control Channels

Supports up to 18 independent high-precision Electronic Pressure/Flow Control (EPC) channels

Optional Inlet

Packed Column Inlet, Cool On-Column (COC) Inlet, Programmed Temperature Vaporization (PTV) Inlet, Gas Sampling Valve (GSV) Injection System, Headspace (HS) Sampling System, Thermal Desorption (TD) Sample Introduction System

Injector

Standard Configuration

Syringe (Manual injection)

Optional Injector

Liquid Autosampler

Headspace Sampler

Gas Sampling Valve

SPME Autosampler

Thermal Desorption Unit

Oven System

Temperature Control Accuracy

±0.01 °C

Maximum Programmed Heating Rate

≥250 °C/min

Number of Programmed Temperature Steps

≥99 steps / 100 platforms (expandable)

Cooling Time

450 °C → 50 °C < 4.5 min (with optional extra cooling unit can reduce to 3.2 min)

Oven Temperature Range

Ambient temperature +2 °C to 450 °C

Temperature Stability

±0.01 °C (column temperature fluctuation < ±0.01 °C at ±1 °C ambient variation)

Maximum Single Step Runtime

100,000 min

Detector

Standard Configuration

Flame Ionization Detector(FID)

Optional Detector

Thermal Conductivity Detector (TCD)

Flame Photometric Detector (FPD)

Nitrogen-Phosphorus Detector (NPD)

Detector Capacity

Up to 4 detectors simultaneously (maximum)

Previous: 
Next: 
Get Quotation/Become Distributor

About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy