Availability: | |
---|---|
Quantity: | |
Model | SP-FL96 |
---|---|
Excitation Light Source | High brightness LED |
Excitation LED | 250nm ~ 600nm(LED) |
EX wavelength standard set: 365nm,376nm,392nm,405nm | |
Emission Monochromator | C-T configuration diffraction grating monochromator Emission wavelength range (EM): 200nm-650nm, Bandwidth: 10nm |
(Extend the monochromator to Em200-900 is optional.) | |
Emission wavelength accuracy: ± 1nm | |
Emission wavelength reproducibility: ≤ 0.5nm | |
S/N Ratio | S/N≥90 (Using 1cm quartz sample cell, measure the signal noise ratio of Raman spectrum of water) |
Detection Limit | 1×10-10 g/ml quinine sulfate solution |
Linearity (γ) | ≥0.995 |
Repetitive Peak Intensity | ≤1.5% |
Zero Drift | ≤0.3 (within 10min) |
Upper Limit Change of Indicating Value | ≤1.5% (Within 10 minutes) (displaying value≥50) |
Power Type | 220V±22V; 110V±22V |
Size (W×D×H)(mm) | 442×392×250 |
Shipping Size (W×D×H)(mm) | 535x500x380 |
N.W./G.W. (kg) | 10/15 |
Reliable cold light source, with low power consumption, long life and other advantages.
High detection sensitivity is suitable for analysis and measurement of ultra-low concentration samples.
Fluorescence intensity mode allows fluorescence spectrum scanning, fluorescence kinetic determination and quantitative analysis.
Provide ten emission spectrum scanning speed selection, can complete the full spectrum scanning within 1 second.
Model | SP-FL96 |
---|---|
Excitation Light Source | High brightness LED |
Excitation LED | 250nm ~ 600nm(LED) |
EX wavelength standard set: 365nm,376nm,392nm,405nm | |
Emission Monochromator | C-T configuration diffraction grating monochromator Emission wavelength range (EM): 200nm-650nm, Bandwidth: 10nm |
(Extend the monochromator to Em200-900 is optional.) | |
Emission wavelength accuracy: ± 1nm | |
Emission wavelength reproducibility: ≤ 0.5nm | |
S/N Ratio | S/N≥90 (Using 1cm quartz sample cell, measure the signal noise ratio of Raman spectrum of water) |
Detection Limit | 1×10-10 g/ml quinine sulfate solution |
Linearity (γ) | ≥0.995 |
Repetitive Peak Intensity | ≤1.5% |
Zero Drift | ≤0.3 (within 10min) |
Upper Limit Change of Indicating Value | ≤1.5% (Within 10 minutes) (displaying value≥50) |
Power Type | 220V±22V; 110V±22V |
Size (W×D×H)(mm) | 442×392×250 |
Shipping Size (W×D×H)(mm) | 535x500x380 |
N.W./G.W. (kg) | 10/15 |
Reliable cold light source, with low power consumption, long life and other advantages.
High detection sensitivity is suitable for analysis and measurement of ultra-low concentration samples.
Fluorescence intensity mode allows fluorescence spectrum scanning, fluorescence kinetic determination and quantitative analysis.
Provide ten emission spectrum scanning speed selection, can complete the full spectrum scanning within 1 second.