Availability: | |
---|---|
Quantity: | |
The dust particle counter uses an imported high-quality air pump, resulting in lower noise and less electromagnetic interference. The all-stainless steel shell better meets the requirements of GMP. Its system is a brand-new operating system developed based on the Android environment. The software has an upgradable audit trail function that fully complies with relevant international laws and regulations. It has built-in standards such as ISO/EUGMP/CHINESE GMP/FED. It can quickly obtain accurate results according to the standard requirements.
It is suitable for places in industries such as electronics, healthcare, biology, pharmaceuticals, food, cosmetics, and chemicals that have requirements for cleanliness levels of the environment.
Flow Compensation and Calibration Function
Built-in imported gas mass flow meter, with the functions of flow compensation and calibration.
High Sampling Data Precision
The sampling volume has high precision, and the results are more authentic and reliable.
Authority Management
There is a 4-level authority management system, including administrator, auditor, advanced user, and operator.
Data Storage
It can store data of no less than 100,000, 500,000 points, and over 10 million of data information.
Measurement Modes
Manual sampling, normal mode, confidence mode (manual), confidence mode (automatic).
Intuitive Operation
It is equipped with an 8-inch color touch screen, and the extra-large visual interface makes the operation simpler and more intuitive.
Model | DPC-310 |
---|---|
Sampling Flow Rate | 28.3L/min (±5%) |
Particle Size Range | 0.3-10μm |
Particle Size Channels | 0.3μm, 0.5μm, 1μm, 3μm, 5μm, 10μm |
Laser Light Source | Long-life laser diode with a service life of 10 years |
Maximum Sampling Concentration | 35000 particles per liter |
Self-cleaning Time | ≤10min |
Sampling Mode | Confidence (UCL) measurement, ordinary measurement |
Data Security | 3+ level authority management |
Data Memory Capacity | 10 million sets of measurement data, and data can be queried according to the required time period |
Number of Room Settings | 30,000 |
Working Time | Approximately 6 hours of continuous testing |
Screen Display | 8-inch color touch screen (with built-in voice broadcast function) |
Audit Trail Software | In compliance with FDA 21 CFRPart11 |
Printing Method | Built-in thermal printer |
Charging Adapter | Input 100-240V 50Hz, Output 17.5V 5A |
Battery Charging Time | 6 hours |
Data Communication Interface | USB Ethernet interface, wifi |
Usage Environment | 0~40℃, relative humidity 10~90% |
Storage Environment | -30℃~40℃, relative humidity 0~90% |
Shell Material | SS 316 brushed stainless steel |
Net Weight | 7.2kg |
Gross Weight | 8.5kg |
External Size (W×D×H) | 223×302×187mm |
Shipping Size (W×D×H) | 705×525×380mm |
The dust particle counter uses an imported high-quality air pump, resulting in lower noise and less electromagnetic interference. The all-stainless steel shell better meets the requirements of GMP. Its system is a brand-new operating system developed based on the Android environment. The software has an upgradable audit trail function that fully complies with relevant international laws and regulations. It has built-in standards such as ISO/EUGMP/CHINESE GMP/FED. It can quickly obtain accurate results according to the standard requirements.
It is suitable for places in industries such as electronics, healthcare, biology, pharmaceuticals, food, cosmetics, and chemicals that have requirements for cleanliness levels of the environment.
Flow Compensation and Calibration Function
Built-in imported gas mass flow meter, with the functions of flow compensation and calibration.
High Sampling Data Precision
The sampling volume has high precision, and the results are more authentic and reliable.
Authority Management
There is a 4-level authority management system, including administrator, auditor, advanced user, and operator.
Data Storage
It can store data of no less than 100,000, 500,000 points, and over 10 million of data information.
Measurement Modes
Manual sampling, normal mode, confidence mode (manual), confidence mode (automatic).
Intuitive Operation
It is equipped with an 8-inch color touch screen, and the extra-large visual interface makes the operation simpler and more intuitive.
Model | DPC-310 |
---|---|
Sampling Flow Rate | 28.3L/min (±5%) |
Particle Size Range | 0.3-10μm |
Particle Size Channels | 0.3μm, 0.5μm, 1μm, 3μm, 5μm, 10μm |
Laser Light Source | Long-life laser diode with a service life of 10 years |
Maximum Sampling Concentration | 35000 particles per liter |
Self-cleaning Time | ≤10min |
Sampling Mode | Confidence (UCL) measurement, ordinary measurement |
Data Security | 3+ level authority management |
Data Memory Capacity | 10 million sets of measurement data, and data can be queried according to the required time period |
Number of Room Settings | 30,000 |
Working Time | Approximately 6 hours of continuous testing |
Screen Display | 8-inch color touch screen (with built-in voice broadcast function) |
Audit Trail Software | In compliance with FDA 21 CFRPart11 |
Printing Method | Built-in thermal printer |
Charging Adapter | Input 100-240V 50Hz, Output 17.5V 5A |
Battery Charging Time | 6 hours |
Data Communication Interface | USB Ethernet interface, wifi |
Usage Environment | 0~40℃, relative humidity 10~90% |
Storage Environment | -30℃~40℃, relative humidity 0~90% |
Shell Material | SS 316 brushed stainless steel |
Net Weight | 7.2kg |
Gross Weight | 8.5kg |
External Size (W×D×H) | 223×302×187mm |
Shipping Size (W×D×H) | 705×525×380mm |