Difference Between Class II A2 & Class II B2 Biosafety Cabinet

Views: 389     Author: Site Editor     Publish Time: 2023-08-08      Origin: Site

facebook sharing button
linkedin sharing button
pinterest sharing button
twitter sharing button
line sharing button
wechat sharing button
whatsapp sharing button
sharethis sharing button

The main difference between Class II A2 and Class II B2 biological safety cabinets lies in their airflow patterns and levels of protection provided.



Biological Safety Cabinets Airflow Pattern:



Class II A2 biological safety cabinet: Class II A2 cabinets provide personnel protection through a laminar airflow that moves from the back to the front of the cabinet. 70% air is recirculated back into the work area after passing through a HEPA/ULPA filter, which removes contaminants. 30% air exhaust out to environment after passing through a HEPA/ULPA filter to ensure air safety.

 Scitek Class II A2 Biological Safety Cabinet Air Pattern    Scitek 2ft Biosafety Cabinet


Class II B2 biological safety cabinet: Class II B2 cabinets offer both personnel and product protection with a total exhaust airflow. The air is drawn into the cabinet, then 100% air exhausted out through HEPA/ULPA filter to dedicated exhaust systems, preventing the release of hazardous materials into the laboratory.

Scitek Class II B2 Biological Safety Air Pattern   


Protection Levels:



Class II A2 Biological Safety Cabinet: Class II A2 cabinets primarily protect the operator and the environment by filtering the air inside the cabinet and recirculating it. They do not provide protection for the product being worked with, making them suitable for low to moderate risk biological agents.


Class II B2 biosafety cabinet: Class II B2 cabinets offer a higher level of protection by providing a total exhaust system. This setup ensures that all air inside the cabinet is exhausted out of the laboratory, preventing any potential contamination of the laboratory environment and the product being handled. Class II B2 cabinets are suitable for handling high-risk biological agents, toxic chemicals, and radionuclides.


In summary, Class II A2 biological safety cabinets protect the operator and the environment through recirculating air, while Class II B2 cabinets provide a higher level of protection by exhausting all air out of the laboratory, offering both operator and product protection. The choice between Class II A2 and Class II B2 cabinets depends on the level of risk associated with the materials being handled and the specific safety requirements of the laboratory.


Scitek Global is professional manufacture of Biological Safety Cabinets, certified by ISO9001, ISO13485 and ISO14001. Cabinets are certified by ETL, CE and FDA etc. Welcome to choose Scitek Biosafety Cabinets.


About Company​​​​​​​

As a professional lab and medical equipment manufacturer, Scitek Global is certified by ISO 9001, ISO 13485, ISO 45001 and ISO 14001. Almost all our products are certified by ETL, CE and FDA .

Scitek Global looks forward to establishing cooperation with more distributors all over the world, and working together to create greater customer value.

Quick Links

Contact Us
Scitek Global Co.,Ltd
  No. 7000 Jingshi Road, Jinan City, Shandong Province, China
/  +86-531-82893797
  Inquiry: info@scitekglobal.com
Service: 
service@scitekglobal.com
Complaints: 

complaints@scitekglobal.com
 
Scitek Global Inc.
9999 Bellaire Blvd Ste 505, Houston, TX 77036, United States
  +1 (915) 4126735
info@scitekglobal.net
 
Scitek Ethiopia
 tsion@scitekglobal.com
Copyright © 2023 Scitek Global Co., Ltd. All rights reserved.  Sitemap  Privacy Policy