High-performance portable turbidity meter, 2 to 5 points calibration, selectable 4 turbidity units, the meter is suitable for process control and field use.
Model | TB-P100 | |
---|---|---|
Turbidity | Measuring Range | 0 to 1100 NTU/ 0 to 275 EBC/ 0 to 9999 ASBC |
Minimum Resolution (NTU) | 0.01(0~99 ), 0.1(100~999 ), 1(1000~1100 ) | |
Accuracy | ±2% of reading (0~500NTU ), ±3% of reading (501~1000NTU ) | |
Calibration | 2 to 5 points | |
Calibration Standard (NTU) | 0.02 / 10 / 200 / 500 / 1000 | |
Other Specification | Light Source | Infrared-emitting diode, wavelength 850 nm |
Detector | Silicon photodiode | |
Stray Light (NTU) | < 0.02 | |
Sample Vial | 60×25(Ø) mm | |
Sample Volume (ml) | 20 | |
Auto-Power Off | 15 minutes after last key pressed | |
Memory | Stores up to 100 data sets | |
Output | USB communication interface | |
Display | Custom LCD (60×40 mm) | |
Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter | |
Size (W×D×H)(mm) | 180×85×70 | |
Shipping Size (W×D×H)(mm) | 280×80×250 | |
N.W./G.W.(kg) | 0.3/1.5 |
High-performance portable turbidity meter meets the design criteria in ISO 7027.
2 to 5 points calibration using the Formazin Standards.
Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.
Single measurement mode automatically senses and locks a stable reading.
Continuous measurement mode can be used for indexing or matching the sample vials.
Auto-power off effectively conserves battery life.
Setup menu allows setting the number of calibration points, resolution, date and time, etc.
Reset function automatically resumes all settings back to the factory defaults.
Expanded memory stores or recalls up to 100 data sets.
USB communication interface for data transfer or connecting a power adapter to the meter.
Drinking water and beverage industry
Environmental monitoring and other industrial applications
High-performance portable turbidity meter, 2 to 5 points calibration, selectable 4 turbidity units, the meter is suitable for process control and field use.
Model | TB-P100 | |
---|---|---|
Turbidity | Measuring Range | 0 to 1100 NTU/ 0 to 275 EBC/ 0 to 9999 ASBC |
Minimum Resolution (NTU) | 0.01(0~99 ), 0.1(100~999 ), 1(1000~1100 ) | |
Accuracy | ±2% of reading (0~500NTU ), ±3% of reading (501~1000NTU ) | |
Calibration | 2 to 5 points | |
Calibration Standard (NTU) | 0.02 / 10 / 200 / 500 / 1000 | |
Other Specification | Light Source | Infrared-emitting diode, wavelength 850 nm |
Detector | Silicon photodiode | |
Stray Light (NTU) | < 0.02 | |
Sample Vial | 60×25(Ø) mm | |
Sample Volume (ml) | 20 | |
Auto-Power Off | 15 minutes after last key pressed | |
Memory | Stores up to 100 data sets | |
Output | USB communication interface | |
Display | Custom LCD (60×40 mm) | |
Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter | |
Size (W×D×H)(mm) | 180×85×70 | |
Shipping Size (W×D×H)(mm) | 280×80×250 | |
N.W./G.W.(kg) | 0.3/1.5 |
High-performance portable turbidity meter meets the design criteria in ISO 7027.
2 to 5 points calibration using the Formazin Standards.
Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.
Single measurement mode automatically senses and locks a stable reading.
Continuous measurement mode can be used for indexing or matching the sample vials.
Auto-power off effectively conserves battery life.
Setup menu allows setting the number of calibration points, resolution, date and time, etc.
Reset function automatically resumes all settings back to the factory defaults.
Expanded memory stores or recalls up to 100 data sets.
USB communication interface for data transfer or connecting a power adapter to the meter.
Drinking water and beverage industry
Environmental monitoring and other industrial applications