Availability: | |
---|---|
Quantity: | |
Model | MWQ-B600 | |
---|---|---|
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 0~19990 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Standard Recognition | 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000 mg/L~1000 g/L |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.0001 | |
Accuracy | ±0.1% | |
Dissolved | Range | 0.00 to 99.99 mg/L |
Oxygen Concentration – Polarographic | Resolution | 0.01 mg/L |
Accuracy | ±0.1 mg/L | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 6-pin Mini-DIN | |
Conductivity with Temp. Probe | 8-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 280×280×130 | |
Shipping size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 2.5/4 |
Scitek's MWQ-B600 is a multiparameter water quality meter. It can simultaneously measure pH, mV/ORP, pX, ISE, Conductivity, etc. It can detect water quality in all aspects to ensure water safety. It adopts high precision algorithm chip and electrode to ensure fast and accurate response.
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
7.0-inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
Can save 1000 groups of data for easy access and retrieval.
IP54 waterproof
Model | MWQ-B600 | |
---|---|---|
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1~2 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 0~19990 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Standard Recognition | 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000 mg/L~1000 g/L |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.0001 | |
Accuracy | ±0.1% | |
Dissolved | Range | 0.00 to 99.99 mg/L |
Oxygen Concentration – Polarographic | Resolution | 0.01 mg/L |
Accuracy | ±0.1 mg/L | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -5 to 130 ºC |
Unit | ºC | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 6-pin Mini-DIN | |
Conductivity with Temp. Probe | 8-pin Mini-DIN | |
Outputs | USB, RS 232 | USB 2.0 flash memory device, printer, PC |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 280×280×130 | |
Shipping size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 2.5/4 |
Scitek's MWQ-B600 is a multiparameter water quality meter. It can simultaneously measure pH, mV/ORP, pX, ISE, Conductivity, etc. It can detect water quality in all aspects to ensure water safety. It adopts high precision algorithm chip and electrode to ensure fast and accurate response.
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
7.0-inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
Can save 1000 groups of data for easy access and retrieval.
IP54 waterproof