Availability: | |
---|---|
Quantity: | |
Model | MWQ-B500 | |
---|---|---|
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% of reading whichever is greater | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1E-9 to 9.999E9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
Resolution | 0.001 μS/cm minimum, | |
various with range selection | ||
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000~1000 ppt |
Resolution | 0.001 ppm minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.0001 | |
Accuracy | ±0.1% | |
Dissolved Oxygen Concentration – Polarographic | Range | 0.00 to 99.99 mg/L |
Resolution | 0.01 mg/L | |
Accuracy | ±0.3mg/L (0.00 to 20.00 mg/L); | |
±10% (20.00 to 99.99 mg/L) | ||
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer, scanner, auto-sampler | |
Display Options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 220×195×68 | |
Shipping Size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 0.95/5.5 |
Scitek's MWQ-B500 is a multiparameter water quality meter that can measure pH, mV/ORP, pX, ISE, Conductivity, etc. It can detect water quality in all aspects to ensure water safety. It adopts high precision algorithm chip and electrode to ensure fast and accurate response.
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
7.0-inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
Can save 1000 groups of data for easy access and retrieval.
IP54 waterproof
Model | MWQ-B500 | |
---|---|---|
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% of reading whichever is greater | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1E-9 to 9.999E9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
Resolution | 0.001 μS/cm minimum, | |
various with range selection | ||
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000~1000 ppt |
Resolution | 0.001 ppm minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.0001 | |
Accuracy | ±0.1% | |
Dissolved Oxygen Concentration – Polarographic | Range | 0.00 to 99.99 mg/L |
Resolution | 0.01 mg/L | |
Accuracy | ±0.3mg/L (0.00 to 20.00 mg/L); | |
±10% (20.00 to 99.99 mg/L) | ||
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data Management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer, scanner, auto-sampler | |
Display Options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
IP Rating | IP54 | |
Date and Time | Yes | |
General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
Sizes(W×D×H) | 220×195×68 | |
Shipping Size (W×D×H)(mm) | 370×305×330 | |
N.W./G.W. (kg) | 0.95/5.5 |
Scitek's MWQ-B500 is a multiparameter water quality meter that can measure pH, mV/ORP, pX, ISE, Conductivity, etc. It can detect water quality in all aspects to ensure water safety. It adopts high precision algorithm chip and electrode to ensure fast and accurate response.
The multiparameter water quality meter has a backlit LCD screen, so you don't have to worry about being unable to read the display at night or in low light.
Automatic Temperature Compensation (ATC) ensures accurate results at any temperature.
7.0-inch LCD
Multiple readings
The lightweight and convenient design allows you to take measurements anytime, anywhere
Ideal for drinking water, hydroponics, aquariums, aquaculture, laboratories, and food processing industries
Can save 1000 groups of data for easy access and retrieval.
IP54 waterproof