Model | WH-B932 | |
---|---|---|
Water Hardness | Range | 0.05~200mmol/L, 0~1122°dH, 0~2000°fH, 0~1404°e, 0~8020mg/L (Ca2+), 0~19999mg/L (CaCO3), 0~11220mg/L (CaO) |
Resolution | 0.001,0.01,0.1,1 | |
Accuracy | ±1% F.S. | |
Calibration Points | 2 to 5 points (0.01, 0.1, 1, 10, 100mmol/L) | |
Temperature | Range | 0.0~105.0°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C | |
Offset Calibration | 1 point, reading +10°C | |
Other Specifications | Temperature Compensation | 0~50°C, manual or automatic |
Stability Criteria | Low or high | |
Calibration Due Alarm | 1 to 31 days or off | |
Memory | 500 data sets | |
Communication Interface | USB | |
Connector | BNC, 3.5mm jack socket | |
Display | Custom LCD (125×100mm) | |
Power Requirements | DC5V power adapter | |
Sizes(W×D×H) | 310× 240×190 | |
Shipping Size (W×D×H)(mm) | 300x250x200 | |
N.W./G.W. (kg) | 1.5/2 |
This is the standard water hardness meter commonly used in laboratories. It provides accurate and reliable results for a variety of tests in laboratory environments, including quality control, water treatment, and more. The high-definition display clearly shows water hardness levels. This water hardness tester is low-maintenance, ensuring that the tested water quality meets the standards required for a variety of applications.
Automatic temperature compensation ensures accurate measurements over the entire range.
Automatic endpoint lockout, retaining stable readings for easy viewing and logging
2 to 5 point calibration, from low to high concentrations
High measurement accuracy: 1% F.S.
The meter is fitted with a U.K. water hardness electrode
Ideal for measuring calcium and magnesium ion concentrations in water.
Model | WH-B932 | |
---|---|---|
Water Hardness | Range | 0.05~200mmol/L, 0~1122°dH, 0~2000°fH, 0~1404°e, 0~8020mg/L (Ca2+), 0~19999mg/L (CaCO3), 0~11220mg/L (CaO) |
Resolution | 0.001,0.01,0.1,1 | |
Accuracy | ±1% F.S. | |
Calibration Points | 2 to 5 points (0.01, 0.1, 1, 10, 100mmol/L) | |
Temperature | Range | 0.0~105.0°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C | |
Offset Calibration | 1 point, reading +10°C | |
Other Specifications | Temperature Compensation | 0~50°C, manual or automatic |
Stability Criteria | Low or high | |
Calibration Due Alarm | 1 to 31 days or off | |
Memory | 500 data sets | |
Communication Interface | USB | |
Connector | BNC, 3.5mm jack socket | |
Display | Custom LCD (125×100mm) | |
Power Requirements | DC5V power adapter | |
Sizes(W×D×H) | 310× 240×190 | |
Shipping Size (W×D×H)(mm) | 300x250x200 | |
N.W./G.W. (kg) | 1.5/2 |
This is the standard water hardness meter commonly used in laboratories. It provides accurate and reliable results for a variety of tests in laboratory environments, including quality control, water treatment, and more. The high-definition display clearly shows water hardness levels. This water hardness tester is low-maintenance, ensuring that the tested water quality meets the standards required for a variety of applications.
Automatic temperature compensation ensures accurate measurements over the entire range.
Automatic endpoint lockout, retaining stable readings for easy viewing and logging
2 to 5 point calibration, from low to high concentrations
High measurement accuracy: 1% F.S.
The meter is fitted with a U.K. water hardness electrode
Ideal for measuring calcium and magnesium ion concentrations in water.