The electrolyte analyzer is a high-precision laboratory device designed to detect electrolyte levels in human blood, serum, urine and other biological fluids. Through advanced sensing technology, the device is able to quickly and accurately measure key electrolyte parameters such as K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG.
Model | EA-972A | EA-972B | EA-972D |
---|---|---|---|
Test Item | K, Na, Cl | K, Na, Cl, TCO2, AG | K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG |
Sample Types | Serum, Plasma, Whole blood, Cerebrospinal fluid and diluted urine | ||
Sample Consumption | 60-300μL(Item 3 to item 11) | ||
Measuring Technology | Ion Selective Electrode | ||
Analysis Time | 25-40 seconds | ||
Storage | Up to 10000 test results | ||
Printer | Internal thermal printer | ||
Ambient Conditions | 15-40 °C (60-104 F), ≤ 85% humidity | ||
Communication Interface | RS232 | ||
Optional | Auto sampler : 39 positions (Including 5 emergency and 2 QC) | ||
Power Supply | AC220V, 50/60Hz | ||
Sizes(W×D×H)(mm) | 380x270x400 | ||
Shipping Size (W×D×H)(mm) | 510x410x710 | ||
N.W./G.W. (kg) | 7/15 | ||
Measuring range, resolution and accuracy: | |||
Items | Measuring Range | Resolution | Measurement accuracy (CV%) |
K | 0.5 - 20.0 mmol/L | 0.01mmol/L | ≤1.0% |
Na | 15 - 200 mmol/L | 0.1mmol/L | ≤1.0% |
Cl | 15 - 200 mmol/L | 0.1mmol/L | ≤1.0% |
Ca | 0.1 - 6.0 mmol/L | 0.01mmol/L | ≤1.0% |
pH | 4 - 9 pH | 0.01pH | ≤0.5% |
Dynamic real-time display of sample ID, ergonomic design, and user-friendly interface.
Power off at any time to reduce reagent consumption
Power failure protection to avoid data loss
Automatic calibration and two-point correction, adjusting the slope and intercept to ensure the accuracy of the test data.
Automatic liquid level detection and alarm. Real-time diagnosis of system working status
Automatic detection and filtration of tiny bubbles to avoid clogging and ensure accurate measurement.
Multiple cleaning methods to avoid clogging and cross-contamination
Fast measurement speed and wide sample capacity options suit any hospital.
The electrolyte analyzer's screen displays real-time electrolyte concentration data, including important metrics such as sodium, potassium, and chloride, and multiple buttons allow users to quickly select different test modes and set parameters.
The back of the electrolyte analyzer is equipped with switches and slots for easy connection of power supply, data transfer and more.
Standards are used to calibrate instruments and ensure the accuracy of measurements
The electrolyte analyzer is a high-precision laboratory device designed to detect electrolyte levels in human blood, serum, urine and other biological fluids. Through advanced sensing technology, the device is able to quickly and accurately measure key electrolyte parameters such as K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG.
Model | EA-972A | EA-972B | EA-972D |
---|---|---|---|
Test Item | K, Na, Cl | K, Na, Cl, TCO2, AG | K, Na, Cl, iCa, nCa, TCa, pH, TCO2, AG |
Sample Types | Serum, Plasma, Whole blood, Cerebrospinal fluid and diluted urine | ||
Sample Consumption | 60-300μL(Item 3 to item 11) | ||
Measuring Technology | Ion Selective Electrode | ||
Analysis Time | 25-40 seconds | ||
Storage | Up to 10000 test results | ||
Printer | Internal thermal printer | ||
Ambient Conditions | 15-40 °C (60-104 F), ≤ 85% humidity | ||
Communication Interface | RS232 | ||
Optional | Auto sampler : 39 positions (Including 5 emergency and 2 QC) | ||
Power Supply | AC220V, 50/60Hz | ||
Sizes(W×D×H)(mm) | 380x270x400 | ||
Shipping Size (W×D×H)(mm) | 510x410x710 | ||
N.W./G.W. (kg) | 7/15 | ||
Measuring range, resolution and accuracy: | |||
Items | Measuring Range | Resolution | Measurement accuracy (CV%) |
K | 0.5 - 20.0 mmol/L | 0.01mmol/L | ≤1.0% |
Na | 15 - 200 mmol/L | 0.1mmol/L | ≤1.0% |
Cl | 15 - 200 mmol/L | 0.1mmol/L | ≤1.0% |
Ca | 0.1 - 6.0 mmol/L | 0.01mmol/L | ≤1.0% |
pH | 4 - 9 pH | 0.01pH | ≤0.5% |
Dynamic real-time display of sample ID, ergonomic design, and user-friendly interface.
Power off at any time to reduce reagent consumption
Power failure protection to avoid data loss
Automatic calibration and two-point correction, adjusting the slope and intercept to ensure the accuracy of the test data.
Automatic liquid level detection and alarm. Real-time diagnosis of system working status
Automatic detection and filtration of tiny bubbles to avoid clogging and ensure accurate measurement.
Multiple cleaning methods to avoid clogging and cross-contamination
Fast measurement speed and wide sample capacity options suit any hospital.
The electrolyte analyzer's screen displays real-time electrolyte concentration data, including important metrics such as sodium, potassium, and chloride, and multiple buttons allow users to quickly select different test modes and set parameters.
The back of the electrolyte analyzer is equipped with switches and slots for easy connection of power supply, data transfer and more.
Standards are used to calibrate instruments and ensure the accuracy of measurements