Availability: | |
---|---|
Model | WP-G45D | WP-G60D | WP-G90D | WP-G120D | WP-G150D |
---|---|---|---|---|---|
Feed Water | Urban tap water: TDS<200ppm, 5-45℃, 1.0-3.5Kgf/cm2 | ||||
Output Water Quality | Deionized water quality completely conform to the national lab type I water standard stated by GB6682-2008 | ||||
Output | 45L/H | 60L/H | 90L/H | 120L/H | 150L/H |
Inorganic Ion Rejection | 96% | ||||
Soluble Organic Matter Rejection | >99% (molecular weight >100) | ||||
Particulate Matter Rejection Rate | >99% | ||||
Microbial Retention Rate | >99% | ||||
Water Outlet | 2 outlets: RO water and deionized water | ||||
RO Water Quality | TDS <10 ppm * Total salt rejection above 95% | ||||
Deionized Water Quality | Conductivity <0.1us/cm, Resistivity: 10-16MΩ-cm@25°C | ||||
Power Supply | 220V, 50/60Hz, 72-240W | ||||
Standard Configuration | Machine (With 1 set consumable filter inside) + Built-in 11 gallon pressure tank + accessory package | Machine (With 1 set consumable filter inside) + External 11 gallon pressure tank + accessory package | Machine (With 1 set consumable filter inside) + External 60L pressure tank + accessory package | ||
Sizes(W×D×H)(mm) | Machine: 590x430x1010 | ||||
Shipping Size (W×D×H)(mm) | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 60L pressure tank: 430x430x850 | Machine: 730x560x1230 60L pressure tank: 430x430x850 |
N.W./G.W. (kg) | 75/100 | 75/100 | 75/100 | 75/110 | 75/110 |
Double LCD screens, fully automatic microcomputer control system.
Water quality online monitoring system.
Automatic RO membrane anti-scaling flushing program and timed flushing procedures to extend RO membrane lifetime.
Real-time display working status like power, water, pump, flush, water shortage and water full to understand the machine running status.
Floor-standing design, with activated and fixed stand bar at the bottom, easy to install and move.
RO water, deionized water, two water outlets.
Present TDS test pen.
Filter Process:
Stage One: PP Cotton Filter (5-micron Pore Size)
Initial filtration of incoming water to eliminate larger particles, colloids, suspended solids, and other impurities.
Stage Two: Granular Activated Carbon
Efficiently adsorbs odor, color, organic substances, and heavy metals from the water.
Stage Three: Compressed Activated Carbon
Further eliminates residual chlorine, organic compounds, color, odor, and turbidity.
Stage Four: RO Reverse Osmosis Membrane (0.0001 Micron Pore Size)
Effectively removes viruses, heavy metals, and organic impurities from the water.
Stage Five: Deionization Purification Tank
Removes most heavy metals and trace elements, achieving the national laboratory water's first-grade standard.
Model | WP-G45D | WP-G60D | WP-G90D | WP-G120D | WP-G150D |
---|---|---|---|---|---|
Feed Water | Urban tap water: TDS<200ppm, 5-45℃, 1.0-3.5Kgf/cm2 | ||||
Output Water Quality | Deionized water quality completely conform to the national lab type I water standard stated by GB6682-2008 | ||||
Output | 45L/H | 60L/H | 90L/H | 120L/H | 150L/H |
Inorganic Ion Rejection | 96% | ||||
Soluble Organic Matter Rejection | >99% (molecular weight >100) | ||||
Particulate Matter Rejection Rate | >99% | ||||
Microbial Retention Rate | >99% | ||||
Water Outlet | 2 outlets: RO water and deionized water | ||||
RO Water Quality | TDS <10 ppm * Total salt rejection above 95% | ||||
Deionized Water Quality | Conductivity <0.1us/cm, Resistivity: 10-16MΩ-cm@25°C | ||||
Power Supply | 220V, 50/60Hz, 72-240W | ||||
Standard Configuration | Machine (With 1 set consumable filter inside) + Built-in 11 gallon pressure tank + accessory package | Machine (With 1 set consumable filter inside) + External 11 gallon pressure tank + accessory package | Machine (With 1 set consumable filter inside) + External 60L pressure tank + accessory package | ||
Sizes(W×D×H)(mm) | Machine: 590x430x1010 | ||||
Shipping Size (W×D×H)(mm) | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 11 gallon pressure tank: 430x430x650 | Machine: 730x560x1230 60L pressure tank: 430x430x850 | Machine: 730x560x1230 60L pressure tank: 430x430x850 |
N.W./G.W. (kg) | 75/100 | 75/100 | 75/100 | 75/110 | 75/110 |
Double LCD screens, fully automatic microcomputer control system.
Water quality online monitoring system.
Automatic RO membrane anti-scaling flushing program and timed flushing procedures to extend RO membrane lifetime.
Real-time display working status like power, water, pump, flush, water shortage and water full to understand the machine running status.
Floor-standing design, with activated and fixed stand bar at the bottom, easy to install and move.
RO water, deionized water, two water outlets.
Present TDS test pen.
Filter Process:
Stage One: PP Cotton Filter (5-micron Pore Size)
Initial filtration of incoming water to eliminate larger particles, colloids, suspended solids, and other impurities.
Stage Two: Granular Activated Carbon
Efficiently adsorbs odor, color, organic substances, and heavy metals from the water.
Stage Three: Compressed Activated Carbon
Further eliminates residual chlorine, organic compounds, color, odor, and turbidity.
Stage Four: RO Reverse Osmosis Membrane (0.0001 Micron Pore Size)
Effectively removes viruses, heavy metals, and organic impurities from the water.
Stage Five: Deionization Purification Tank
Removes most heavy metals and trace elements, achieving the national laboratory water's first-grade standard.